HomeRuralCheck your storage silos

Check your storage silos

Industry experts are calling on grain growers to assess and either maintain or decommission older silos after a series of high-risk incidents involving collapsing on-farm silos.

Grains Research and Development Corporation (GRDC) grain storage extension team specialist Chris Warrick offered the warning in the wake of several serious, on-farm incidents involving the collapse of silos in southern Australia.

Mr Warrick said while well maintained silos could last in excess of 30 years, growers needed to effectively check, assess and recognise when critical storage equipment was no longer fit for purpose or had been structurally compromised.

“The potential risks to family members or farm staff if a silo fails is very serious, there are also implications for grain or other losses, so this is an issue that growers need to pay attention to,” he said.

“If a silo is not structurally sound, we strongly encourage growers to seek an alternative storage option, make repairs or decommission the silo to prevent further damage, injury or catastrophic failure of the silo.

“Storing pulses and fertilisers can be higher risk than cereal grains, with higher bulk density and different flow characteristics placing greater loads on silos which can cause them to fail if structural weak points are apparent in either the design, materials, corrosion, damage or modifications undertaken.”

Mr Warrick said these commodities required stronger wall sheets and/or wall supports and stronger cone bases than for cereal grains.

“Cracked concrete bases, unlevel bases, damaged silo legs or wall sheets, corroded rivets or bolts are known contributors to silos failing under load.”

He said a checklist for growers assessing silo integrity should include: is the foundation the silo is sitting on stable?; are the support legs and base rings free of damage and rust and in sound condition?; are the wall sheets free of damage and rust?; are all fixings (rivets and bolts) in sound condition?; is the ladder structure (if applicable) in sound condition for safe use?; and does cleaning and operating the silo pose a safety risk?

GRDC northern region grower relations manager Graeme Sandral also urged growers to take extra care when out loading fertilisers as fertilisers absorb more moisture than stored grain.

“Growers should be aware that the northern and western sides of silos often have lower moisture, with higher moisture in the southern side of the silo,” he said.

“This can present risks when out loading with the dry side generally emptying first in the worst-case scenario this can lead to silo collapse.”

In addition to structural integrity, Mr Warrick encouraged growers to consider safe operation as part of the assessment.

“Whether it be for maintenance or monitoring grain, access to the top of silos is necessary so safe access is a requirement,” he said.

“Many older silos have unsafe ladders, some silos have been purchased without ladders, so the decision is to install safe ladders or an elevated walkway or use a mobile boom lift.

“Silos being fit for purpose includes a safe way to access the top.”

Mr Warrick encouraged growers to consider writing a maintenance or decommission plan for silos immediately following loading or out loading when any issues were front of mind.

“The decision to maintain or replace silos is critical for safe farming operations and needs to happen well in advance of harvest,” he said.

GRDC has information resources available via storedgrain.com.au, with the national team of grain storage specialists available by phoning 1800 WEEVIL.

Digital Edition
Subscribe

Get an all ACCESS PASS to the News and your Digital Edition with an online subscription

More fertiliser secured for Aussie farmers

The federal government has announced a deal to facilitate 250,000 tonnes of additional agricultural grade urea for Australian farmers from Indonesia. A deal between Incitec...
More News

Reefs approved for Tumby

The Tumby Bay marine ecosystem is set for a boost as research reef permits have been officially approved at two locations and community members...

Report highlights increased role of canola in biofuel future

A new report has highlighted the key role canola could play as a biofuel in future energy transition and fuel security for Australia. The report,...

Arno Bay grabs big EP Tri Series lead

Host club Arno Bay bolted ahead on team points when the first round of dirt circuit’s EP Tri Series was held there earlier this...

Minbrie mining approved

The landscape of local exploration is set to shift this year as Lincoln Minerals has announced it secured all necessary regulatory and landowner approvals...

Inaugural grain sustainability report unveiled

The Australian grain sector released its first-ever Grain Sustainability Framework (GSF) Annual Report on March 25, establishing a national baseline for key environmental, social...

Nominate now for environmental awards

The 2026 South Australian Landcare Awards have officially opened, celebrating agricultural and environmental champions. The awards are an opportunity to recognise those making a difference...

Applications open for Qantas grants program

Qantas is inviting not-for-profit community groups across regional Australia to apply for a share of $2 million in funding as the airline’s Regional Grants...

New bank office opened

Community Bank Cummins District is excited to have its own location in the Tumby Bay community, with the Tumby Bay Office opening its doors...

Voice is a positive

Dear Editor, It’s good to see the second SA Voice to Parliament election has concluded with positive expectations for the future (‘Far West has its...

Join a growing team making a difference

Eyre Care is a locally built and managed service provider based in Port Lincoln, dedicated to delivering high-quality, person-centred support to the community. Due to...